Powder Springs GA | HVAC Plumbing
R.S. Andrews provides expert HVAC and plumbing service to Powder Springs GA residents.
Call us now at: (770) 913–6412 or check out why your neighbors call us the top-rated heating, air conditioning and plumbing company in Powder Springs GA.
Local Reviews
for Powder Springs, GA
Fantastic service!
Pat - Powder Springs, GA
Josh and his partner were prompt, professional and knowledgable. They made all the repairs I needed and did a fantastic job.
Response from RS Andrews:
Thank you for your review!
Great service
Steve - Powder Springs, GA
Great Service
Richard - Powder Springs, GA
The Technician was very professional and quite experienced in the Plumbing field. He did a great job installing my water heater and cleaned up afterwards.
Response from RS Andrews:
Thank you very much for your review!
Jason H.
returned to install compressor double checked compressor windings- not open cycled a/c cond fan motor operating at half speed(ecm) compressor is not the issue compressor going into thermal overload due to fan motor operation replaced condenser fan motor under warranty cycled a/c multiple times with no issues system operating at 130/327 superheat 16 subcool 15 ambient 92 system operational at this time
Jason H.
We furnished, wired, and replaced attic gable fan at back right of house. We furnished, wired, and replaced the thermostat for said fan. We checked the other 3 attic fans. The front right side one works. The two on the left side do not.
Jason H.
found 19 yr old u/s system low on r22 customer opted to charge system with no guarantee on how long system will stay cooling half of repair today credited toward new equipment for 6 months added 2lbs of r22 superheat now 9 subcool now 13 delta t in range system operational at this time
Brad L.
Estimate on the installation of new 50 gallon 6 year warranty with new expansion tank. will haul away the old heater.
Ben G.
Flush tankless unit with vinegar.Check all filters unit is working good.
Robert W.
Completed Air Conditioner preventative maintenance on one unit.
Micheal Hicks 1508 .
Completed One time tune on one furnace.
Andrew N.
Upstairs furnace no heating. Bad igniter replaced December 2015. Replaced igniter if replacement igniter fails again we will order Oem igniter.
Andrew N.
Furnace not heating due to dirty filter and tripped high limit. Reset limit switch and changed filter.
Brad L.
Quote to replace sink waste Assembly this includes tailpiece the tee going to garbage disposal,new p-trap and basket strainer. Replace an electric water heater with either a ream or a Bradford white Electric water heater this includes a new expansion tank.
Cameron Goss 2103 .
Estimate on installing three customer supplied lavatory faucet and on repairing customers commode in the downstairs powder room.
Brad L.
Estimation to replace sewer line from house to tap this includes two clean outs and 140 foot line manhole is over 19 foot 7 inches from bottom to top .any trees that have to be removed is the customer's responsibility. Estimate to use sewer machine to pull hair roots and blockage from 20 foot from the house depending on how much time it takes.
Todd Malcom 1780 .
Checked upstairs unit for no heat. found two issues with unit.First was inducer wouldn't start by itself without me giving it a little spin.After the helped it the first time it came on fine several times afterwords. just keep eye on inducer. Second issue was the igniter was bad.I replaced igniter and started up unit. Furnace working properly at this time.
Todd Malcom 1780 .
Completed furnace preventative maintenance on two units.
Joshua M.
Installed and adjusted brace box.
Robb C.
Air conditioner not cooing due to basement condensate pump leaking water into pan and tripping safety switch pump .Found system to be slightly low on R22.Recommend leak search.
Cameron Goss 2103 .
Installed new 50 gallon power vent water heater. Installed new explain tank and new cut off to bring water heater up to code. Had to pull a new gas, new water line and power line for the new heater.
Jeff L.
Air conditioner system not operating. Found system locked out on high pressure and adjusted charges. Adjusted hp module settings and zone board settings. Cycled system.
Robert W.
Completed furnace preventative maintenance. Checked and changed filters. Cleaned flame sensors. Checked emergency heat on heat pump.Blower capacitor for main floor furnace and basement air handler tested weak.
Robert W.
Installed new defrost control-still not initiating defrost. according to goodman their heat pumps cannot be tested for defrost under warm conditions. defrost thermostat ok- normally closed opens on rise; does not cycle defrost on only drops it out. charge was 22 superheat added a small amount of freon and washed the outdoor coil. We replaced evaporator coil last year; the flare nut to the piston is leaking; it is snug but will not stop leaking. Will order new flare nut and Teflon o ring and return to install.
Robert W.
Completed furnace preventative maintenance.Cleaned flame sensor and checked all flue connections.
Robert W.
Checked defrost control not initiating a defrost cycle through test. Will order defrost control.
Cameron Goss 2103 .
Estimate to replace water heater.
Ben G.
Ordering a Apollo Pressure reducing valve.
Robert W.
Preventative maintenance on one air conditioner.