cleaned evaporator coil sealed coil exterior to plenum cycled a/c compressor amps ok fan amps ok superheat 10 subcool 14 system is charged properly and is operating as designed at this time
Kevin Richardson 1506 .
Completed Air Conditioner preventative maintenance on one unit.
Kevin Richardson 1506 .
Completed Air Conditioner preventative maintenance on one unit.
Kevin Richardson 1506 .
Completed Air Conditioner preventative maintenance on two units.
Cameron Goss 2103 .
install new sewer drain line,install the home and new commode flanges and we took the 4 inch sewer line all the way to the septic tank. The only thing that is still cast iron is the vents going to the roof and the waste arms in the wall of the bathroom faucets.All the pvc has a 1 year warranty on the line.
Amber D.
Estimate to re-pipe the basement with pvc and cut all the old cast iron pipe.
Brad L.
poked on and off switch with a stick on the well tank and well pump started working, so customer said she did not want to proceed at this point because it is working.
Joshua M.
Came out to determine cause for ceiling fan lights not working. Determined fan is getting proper voltage, removed a bulb from 1 of 3 bad sockets and light is working. To correct issue the fan will have to be replaced.
Andrew N.
Furnace no heating due to zone system not signal from zoning board to furnace. Unit has a bad zoning board.
Brad L.
Gave two estimates for repairs.Fist option install new ball valve for water heater discounted. Second option to install new water heater.
Brad L.
Suggested to customer to replace dishwasher.Customer says dishwasher no longer works it run but it will no longer clean the dishes the parts in the middle does not come out and clean the dishes like it is supposed to.
Pierre Knight 1.
completed furnace preventative maintenance on one unit.
Pierre Knight 1.
Completed furnace preventative maintenance on one unit.
Rodney M.
Gave estimate to replace lavatory faucet, rebuild toilet in upstairs hall bath, and repair sink in hall bath.
Todd Malcom 1780 .
Returned to check downstairs unit. Found no power to furnace. Traced wiring back to problem and found power switch was bad.Bypassed power switch until it can be replaced.
Todd Malcom 1780 .
Checked downstairs unit for no cool.customer said it wouldn't come on when he set the thermostat to lower temperature. when I arrived and turned the thermostat down it came right on. I checked the freon pressures and they were just slightly low. I added 1/2 pounds of freon to unit. Cycled thermostat on and off with no further issues.Informed customer to keep an eye on thermostat. unit cooling properly at this time.
Andrew N.
Air conditioner not keeping up. After inspecting system found pressures low- added 1/2-lb of R-22 into system.Found compressor pulling 17.5 amps of 18.3 amps max. Compressor will fail soon. System needs to be replaced.
Andrew N.
Preventative maintenance on 1 system air conditioning preventive maintenance. Inspected system. Checked blower wheel- dirty and out of balance. Checked run capacitor- Failed- capacitor is at 6.01uF of 10uF- must be replaced. Checked and tightened wiring. Tested condensate pump- pass- safty float switch not hooked up. Checked blower motor amperages- high. Rinsed out washable filter. Cycled A/C. Checked start capacitors- ok. Checked and tightened contacts- contactor is burnt and pitted. Checked compressor and condencer fan motor amperages- ok. Checked system pressures- low- added 1-lb 4-oz of R-22 into system- no guarantee on refrigerant due to leaks. Evaporator coil is rotted out. Found disconnect handle broken- not safe. System is in very poor condition due to age and wear. Furnace needs a heat exchanger inspection done before use do to possible health hazards.
Andrew N.
Technician ordered 60A disconnect box.
Ben G.
Quoted to install customer supply kitchen sink faucet total ,clear kitchen drain with hand top ,rebuilding toilet new fill valve,flush valve,flapper and supply with new tank to bowl kit,rebuild hose Bib at garage,replace shower head in master bath customer supply.
Gasper L.
HVAC installation of Lennox 4 ton 14 ACX AC complete system
Andrew N.
HVAC repair to leaking unit in the attic.
Andrew N.
Repaired HVAC unit
Harry S.
Replaced garbage disposal, no leaks.
Kenny R.
Preventive Maintenance on HVAC system