Jason H.
We checked motor for the attic fan. Found attic fan motor seized. Furnished, wired, and replaced said attic fan. Temperature has been set on 95.
Jason H.
Furnished, wired, and installed 2 switches and switchlegs for Undercabinet lights in the kitchen. Wired and installed customer provided Undercabinet lights in said kitchen. Performed panel maintenance and tightened all connections. We had to cut Sheetrock. We do not patch any Sheetrock that we cut.
Jason H.
Replaced pressure reducing valve. Set pressure to 60 psi. Tested for leaks and non found. Replaced expansion tank. Pumped up to 60 psi. Tested and no leaks. Replaced the gas to both furnaces so that black iron comes out of the furnace per code. Cleared master bath left side sink. Found hair in the drain. Drains good with no gurgling.
Jason H.
install 1 inch prv on the main to lower psi below 80
Jason H.
install new 50 gal water heater up to code with a new thermal expansion tank and cut off with removal of the old unit 6 year rheem
Jason H.
Installed gas line with two cut offs for a gas grill Line is installed with 1/2 type l copper
Jason H.
We troubleshot and fixed reversed polarity issue on the outlets in the basement. We troubleshot and fixed non gfi protected outlets at the front and back of home. We furnished, wired, and installed a gfi in the garage to replace exposed wiring. We performed panel maintenance and tightened all connections. We furnished, wired, and replaced a total of 3 breakers that were installed improperly. During panel maintenance, we found bundled up neutrals which is against code. We furnished, wired, and installed an additional neutral bar and separated said neutrals.
Jason H.
Walked job with customer to give a price.
Jason H.
Customer has a house standing pressure of 105PSI from PRV (Pressure Regulating Valve). Replaced the single port 3/4" PRV with a new 3/4" duel port PRV. Replaced the T&P valve on the 50 gallon gas water heater. There is a one year warranty on both items. All tested great with no leaks. Pressure is now at 60PSI.
Jason H.
install #6 bare copper to a ground rod to properly bond the panel
Jason H.
moved a gas line back in the wall so that customer could put the new stove flush to the wall also the company that installed the stove to start with. had 2 gas leaks on the line
Jason H.
we rebuilt back bathroom commode we rebuilt the back master bathroom commode that we recommend customer change out to ensure that he doesn't have future problems we rebuilt master bathroom faucets we installed a new commode in the hall powder room bath we also snaked the office bathroom commode
Jason H.
rebuilt on the down stairs commode
Jason H.
the water heater was not leaking it was the female connection on the hot side The connection was not tight. we cut it out and replaced it
Jason H.
installed two sink faucets and trim one shower.
Jason H.
non club tankless W/H is not working error code leading toward pump
Gasper L.
Install lennox 4 ton xc25 ac compl sys in bsmt upflow 21" wide 80% 110k btus w/vspd furnace, new april aire humid #800 steam, new s-30 stat, new supply plenum 21" wide, no filter rack needed. install lennox 1.5 ton xc14 ac compl sys in bsmt upflow 14" wide 80% 70k btus. new pro 8000, new supply plenum 14" wide, no filter rack needed. Install lennox 2 ton xc16 ac compl sys in attic upflow 14" wide 80% 70k btus w/vspd furnace, new pro 8000, new supply plenum 14" wide reinstall bypass humid existing a/a., no filt rack needed also warr
Joshua M.
Troubleshooted hot tub gfi breaker. furnished, wired, and replaced said hot tub breaker panel with a new 50 amp hot tub breaker panel. performed panel maintenance and tightened all connections.
Joshua M.
Completed a basic diagnostic of the closet light and switch.
Robb C.
Completed Air Conditioner preventative maintenance on one unit.
Robb C.
Completed Air Conditioner preventative maintenance on three units.
Robb C.
Completed Air Conditioner preventative maintenance on one unit.
Robb C.
Completed air conditioner preventative maintenance on one unit.
Ben G.
Estimate on changing out lavatory faucets and drains with new supply lines and pop up customer supply.
Robert W.
Rechecked charge on equipment-running 311/99 which is within the specs for a 42-46 degree day. would like to recheck charge in cooling mode on a day above 70 degrees. adjusted air flow for living room to 1200 cfm to improve capacity and efficiency for this zone. after adding up duct work on this zone it may be necessary to make changes to how the air is being delivered.